Six inches wider than a standard 48" gypsum board panel, Stretch54 reduces the number of joints in nine-foot walls for a smoother surface, critical for today's thinner wallpapers and new no-texture finishes. That’s because two standard-width boards come up one foot short when hanging panels on nine-foot walls. A one-foot filler strip must be used to complete the wall, which also adds an additional joint to tape and float.
Features:
- Lower costs: Fewer boards and seams means reduced material and labor costs.
- Less time: Stretch54 covers more area faster than conventional 48" board.
- Reduced waste: Cut fewer pieces by eliminating gap fillers.
- Stronger, smoother walls: Horizontal installation increases wall strength while reducing the number of joints.
Product Specifications:
| | Federal Specification SS-L-30D | Product Standard
ASTM | Installation Standards |
1/2" (12.7 mm)
Regular |
Type III & Grade R | C1396 | ASTM C840, GA216 |
1/2" (12.7 mm)
Fire Resistant |
Type III & Grade X |
C1396 | ASTM C840, GA216 |
5/8" (15.8 mm)
Fire Resistant |
Type III & Grade X |
C1396 | ASTM C840, GA216 |
| | 1/2" (12.7 mm) Regular | 1/2" (12.7 mm)
Fire Resistant | 5/8" (15.8 mm)
Fire Resistant |
| Width |
54" (1371 mm) |
54" (1371 mm) |
54" (1371 mm) |
| Length |
10' to 16'
(3048 mm to 4876 mm) |
10' to 14'
(3048 mm to 4267 mm) |
10' to 14'
(3048 mm to 4267 mm) |
| Weight |
1.6 lbs/ft2 |
1.6 lbs/ft2 |
2.33 lbs/ft2 |
| Edge |
Tapered |
Tapered |
Tapered |
Special Order Information:
Other widths, edges and lengths may be available on special order with established minimums and lead time. Some products may not be available in all markets. Please check with your local Temple-Inland sales representative.
Limitations:
- Designed for interior use only
- Avoid exposure to prolonged, excessive temperatures: 125°F (52°C)
- Avoid exposure to excessive or continuous moisture
- Must be protected from direct exposure to weather and properly supported to prevent sag
- Should be stored, handled and installed to comply with industry standards GA216 & ASTM C840
Fire Resistance of 5/8" Type X Panels:
This material has been fire tested in accordance with the requirements of ASTM E119 and therefore may provide a fire rating of one or more hours, depending on the system in which it is applied. Because ASTM procedures require that fire tests be conducted on complete building assemblies/systems and not just on the board itself, the ability of any particular 5/8" Type X gypsum board to pass a specific ASTM fire test may well depend on factors other than the fire resistance of the gypsum board being tested. These factors include the other components used to construct the building system being tested, the manner in which the system is constructed and the inherent variability of ASTM fire tests. See our Fire-Resistant Gypsum Board page for more information.
Low VOC-Emitting Material:
Temple-Inland gypsum board products are third-party certified by Materials Analytical Services, LLC (MAS) to meet the performance standard established for low-emitting materials under the Collaborative for High Performance Schools (CHPS) Program.
Sulfur Emissions Testing:
In emissions level testing for carbon disulfide and carbonyl sulfide conducted by Materials Analytical Services (MAS), Temple-Inland gypsum board was determined to be negative for sulfur off-gassing and is not considered a problematic corrosive drywall type.
Storage:
Gypsum wallboards should be carried, never dragged, to prevent damaging the finished edges. When storing gypsum boards, store them indoors and protect them from weather and direct sunlight. Boards should be stored lying flat and neatly stacked. Care should be taken to prevent sagging or damage to edges, ends and surfaces. Placing boards against framing is not recommended.